Weekly certificate of chemical and physical tests. Twiga Ordinary, Cem II Class 32.5 N 09
th to 15
th July, 2007
Sampled and tested in accordance with the requirements of the Tanzanian standard
TZS 727:2002. Equivalent to EN 197 - 1
| Test |
Unit |
Results |
Specified requirements |
| Initial setting time |
minutes |
148 |
More than 75 minutes |
| Soundness (expansion) |
mm |
1.0 |
Less than 10.0 mm |
| Compressive strength 2 days |
MPa |
13.6 |
More than 10 MPa. |
| Compressive strength 28 days* |
MPa |
35.4 |
Between 32.5 and 52.5 MPa |
Remarks: * Cement dispatched during week 24/2007
Wazo Hill, 2007/07/18